P. LEO OBJT2 UL File E491285
P. LEO OBMW2 UL File E158033
Single- and Multi-layer Insulated Winding Wire - Component

Cat. No.

Insulation Type

TIW ConductorSize Range

TempClass°C

Rated
Volts
UL
60950-1
V peak

Rated
Volts
UL
60601-1
V peak

Rated
Volts
UL 61800-
5-1
V rms

1PAM(18-32)xx@+ [c]

Basic

32-18 AWG

130(B)

1000

2PFA(29-38) xx@ [c]

Supplementary

38-29 AWG

130(B)

1000

3ETF(18-32) xx@+ [c]

Reinforced

32-18 AWG

130(B)

1000

3ETF(18-32) xx@SB+ [c]

Reinforced

32-18 AWG

130(B)

1000

3FEP(size) xx@+ [c]

Reinforced

32-18 AWG

130(B)

1000

1PAM(18-32)xx@ [c]

Basic

32-18 AWG

155(F)

1000

2PIM(size)xx@ [c]

Reinforced

0.35-2.5 mm

155(F)

1410

707

3ETF(11-39)xx@ [c]

Reinforced

39-11 AWG

155(F)

1410

600

3ETF(11-39)xx@SB [c]

Reinforced

39-11 AWG

155(F)

1410

600

3FEP(18-32)xx@+ [c]

Reinforced

32-18 AWG

155(F)

1000

3FEP(18-32)xx@SB+ [c]

Reinforced

32-18 AWG

155(F)

1000

3TPN(18-39)xx@ [c]

Reinforced

39-18 AWG

155(F)

1000

600

3TPN(18-39)xx@SB [c]

Reinforced

39-18 AWG

155(F)

1000

600

2PFA(size)xx@ [c]

Supplementary

0.095-1.024 mm

180(H)

1000

Cat. No.

Insulation Type

TIW ConductorSize Range

TempClass°C

Test
Voltage
V

FIW-X B[a]

Reinforced

39-15 AWG

130(B)

3000

FIW-X F[a]

Reinforced

39-15 AWG

155(F)

3000

[a] - X may be prefixed by 0 thru 10 indicating the coating thickness.

[c] - @ optional, indicates numerical value between 3-9, xx replaced by one or two letter(s) or numbers.

Marking: Company name or trademark,, material designation and the Recognized Component Mark, On the smallest unit container In which the product Is packaged, spool, Or On a tag attached To the End Of the wire.

Following is the construction of our part number :

Part number : 2 PIM (size) xx @

(A)Number of layer : 1, 2, 3

(B)Insulation type :

PAM = PA66 Nylon

ETF = ETFE

FEP

PFA

PIM = Polyimide Tape wrapped Litz wire

(refer to #3PIM (0.35-2.5mm) Reinforced Class F insulation.)

TPN = ETFE+ETFE+PEN

(C)(size) AWG18-32, 29-38, 18-39, 11-39, and 0.35-.5mm and 0.095-1.024mm

(D)xx --C Replaced by one or two letter(s) or numbers to indicate the following :

Two digits = R/C -C Magnet Wire (OBMW2), ANSI MW type : MW79, MW80, MW82, MW83 LZ = Litz Wire. And When it used in the EIS system, the used magnet wire need to be existed in the EIS system.

Conductor: XX in the designation system is replaced by the following:

BC = Solid Bare Copper; BA = Bare Aluminum; TC = Tinned copper; NC = Nickel plated copper,

or two digits indicating the MW type which is R/C -C OBMW2,

magnet wire designated XEUW-F, MW 79C Type

(E)@  optional, Indicates numerical value between 3-9   (color code)

SB   self bonding

UL Recognized Component        Copyright © 1996-2022 P. LEO & Co., Ltd., All rights reserve.