UL Electrical Insulation Systems

gold line

Du Pont           UL FILE NO. E69939, CLASS B (130 degree C) ELECTRICAL INSULATION SYSTEMS
SYSTEM DESIGNATIONGROUND INSULATIONVARNISHLAYER & PHASEMAGNET WIRETAPESSLEEVING
BCtube
LEAD WIRETIE CORESPACER, STICK WEDGES, SHEET
Z150SC1
Zytel 101L, E101L, 101F, 103HSL, E103HSL, 132F, 70G13L, 70G30HSL, 70G33L, 70G33HS1L, FR50, Nomex, 0.13mm (5mil) Mylar, 0.13mm (5mil) ISONEL 31-398; ISONEL 51; 13 TYPESMW24;MW26;
MW28;MW80; MW75;MW79
Tape, 3M Tape & OthersVARFLEX9 TYPES2 TYPES23 TYPES
Z150RZytel 101L, E101L, 101F, 103HSL, E103HSL, 132F, 70G13L, 70G30HSL, 70G33L, 70G33HS1L, FR50, Nomex, 0.13mm (5mil) Mylar, 0.13mm (5mil)Ripley Resins,
468-2, 468-2FC, 468-27 and Potting Compounds
16 TYPESMW 26; MW28;MW80 Tape, 3M Tape & Others4 TYPES9 TYPES2 TYPES18 TYPES
Z150N1Zytel 101L, E101L, 101F, 103HSL, E103HSL, 132F, 70G13L, 70G30HSL, 70G33L, 70G33HS1L, FR50, Nomex, 0.13mm (5mil) Mylar 0.025mm (1mil), P.Leo Tape 1P801, 1P802 Nil 10 TYPESMW28 MW24 MW26 MW75 MW79 MW80 MW5 MW30 MW35 MW73 MW74 MW76 MW27 MW77 MW78 Tape, 3M Tape & OthersVARFLEX
BCtube
7 TYPES6 TYPES13 TYPES
Du Pont            UL FILE NO. E69939, CLASS F (155 degree C) ELECTRICAL INSULATION SYSTEMS
R281SCRynite 530, 530L, 935, FR515, FR530, FR530L, FR945, RE9057, Nomex 0.13mm (5 mil)Schenectady ISONEL 31-398; ISONEL 885, 862, 91610 TYPESMW 35; MW76 Tape, 3M Tape & OthersVARFLEXTEFLON4 TYPES12 TYPES
RZ202RRynite 415HP, FR530, FR530L, Nomex 0.13mm (5 mil)Ripley Resins, 468-2, 468-2-7, 468-2FC, Potting Compounds 477-5LL, C-100, C-100-L1MNOMEXMW30 MW35 MW74 MW76 Tape, 3M Tape & others   3 TYPES
R201NRynite FR530, FR515, FR330 0.4mm(15mil) Nomex 410, 414, 418 0.08mm (3 mil), Mylar 0.08mm (3mil)NilNOMEXMW26 MW76 MW80 Tape, 3M Tape & othersVARFLEX  3 TYPES
Z200NZytel 70G30HSL, 70G33L, 70G33HS1L, EFE7168HSL 0.4mm(15mil), Nomex 410 0.08mm (3mil) Mylar, 0.08mm (3mil)Nil16 TYPESMW76;MW80 Tape, 3M Tape & Others4 TYPES9 TYPES2 TYPES18 TYPES
Du Pont            UL FILE NO. E69939, CLASS H (180 degree C) ELECTRICAL INSULATION SYSTEMS
R372SCRynite FR530, FR530L, 530, 530L, FR945 935, (28 mil), Nomex 410 8.5mil Schenectady 550, 771, 51, 802, 31-398, 885 NOMEXMW 35 Tape, 3M Tape & OthersVARFLEX12 TYPESVARFLEX4 TYPES
R315R1Rynite 530, 530L, FR530, FR530L, FR543, 0.4mm Nomex 0.13mm Ripley Resins, 468-2, 468-2-7, 468-2FC Potting Compounds C-100, C100-L1M, 471-5LL NOMEX MW35 Bare Wire Wrapped with 0.05mm Nomex Tape3M Tape & Others   8 TYPES
Du Pont            UL FILE NO. E69939, CLASS N (200 degree C) ELECTRICAL INSULATION SYSTEMS
R400N2Rynite FR530, FR530L, 1.07mm. Nomex 0.23mm ISONEL 31; ISONEL 31-398; ISONEL 31-66; ISOPOXY 771; ISONEL 51; ISONEL51-66HF; AQUANEL 550; ISONEL 885; ISONEL 793; ISONEL 794; ISONEL 802; ISONEL 862NOMEXMW 35 Tape, 3M Tape & OthersVARFLEX12 TYPESVARFLEX4 TYPES
R400RRynite 530, FR530, 0.75mm. Nomex 0.23mm ISONEL 31; ISONEL 31-398; ISONEL31-66; ISONEL 31B; ISONEL 51; ISONEL 51-66HF; ISONEL 472; ISONEL 472-66; ISONEL 2991; ISONEL 322A; ISONEL 773; ISONEL 433; ISOPOXY 433-50 NOMEXMW 35 Tape, 3M Tape & Others   8 TYPES


DuPont "Encapsulated" EIS

UL File No. E69939 (Evaluated in Accordance with IEC Publication 85)

    The insualtion systems listed below may be used as either encapsulated ("open") systems for applications such as transformers, motors or solenoids under 600 V

    These systems are based on gournd insulation and encapsulants made from thermoplastic Rynite ® polyester resin.

DuPont Electrical Insulation Systems for Encapsulated Applications
System
Designation
Ground
Insulation (1)
Magnet
Wire (2)
Encapsulant
Class B (130 oC) System, 600 V maximum
R181EN
Rynite FR530,
0.75 mm (28 mil)
MW28
Rynite FR530,
1.07 mm (40 mil)
R189EN
Rynite 530,
0.75mm (28 mil)
MW28
Rynite 415HP,
0.83 mm (31 mil)
Class F (155 oC) System, 600 V maximum
R211EN
Rynite FR530,
0.75mm (28 mil)
Nomex 0.13 mm (5 mil)
MW80
Rynite 415HP,
0.83 mm (31 mil)
Class H (180 oC) System, 600 V maximum
R380EN
Rynite 5220,
0.75mm (28 mil)
Nomex 0.13 mm (5 mil)
MW35
Rynite 5220,
0.83 mm (31 mil)

1)Thickness (eg., 5 mil 28 mil, etc.) is minimum thickness allowed.
2) Please click according to see the table for allowable magnet wire substitutions.

If you are having any question about the UL Electrical Insulation Systems
e-mail at sales@pleo.com


NOTICE : This information , based upont UL Testing Guidelines and our experience, is offered without charge by Dupont as part of our service to customers. It is intended for persons having technical skill to use at their own discretion and risk. We do not guarantee favorable results, and the DuPont Company & P. Leo assumes no obligation or liability for any advice furnished or for any results obtained to operae under, or a recommendation to infringe upon, any patent of DuPont or others. Compliance with applicable government codes is also the responsibility of the user.

back to main to tape
Back to Main Page

Back to UL SYSTEM Web Page


® Registered trademark of Underweriters Laboratories, Inc.

Zytel ® Rynite ® Zenite® Kapton ® Mylar ® and Nomex® are Du Pont trade marks.

Copyright © 1996 P. Leo & Co., Ltd.. All rights reserved. Reproduction in whole or in part in any form or medium without express written permission of P. Leo & Co., Ltd. is prohibited. BCwire ; pBobbin ; BCmica & are trademarks of P. Leo & Co., Ltd.